LogNov 25 ,20199:30 could not receive DACHS card at bld.6 (Because My name was not in the database.) 10:30 registered my name in the database at bld.6 room 208 11:30 received DACHS card 13:00 safety training(listen and sign name,no test) 14:00 setup move last TB config file (ex.V2Sxx.json) to Sep2019_2 directory make new connectivity config file:vendor6.json![]() | ||||||||
Added: | ||||||||
> > | 26 Nov, 2019 | |||||||
Deleted: | ||||||||
< < | 26 Nov | |||||||
9:00 maybe the promble was due to Single Chip Card? (1) module connect with only HV -> stable, 10(?)nA@-80V (2) module connect with HV and DiplayPort -> unstable:often drop to 0 A (3) module connect with HV and DisplayPort and LV power supply (ON) -> unstable (4) module connect with HV and DisplayPort and LV (ON). LV GND and YARR GND short -> unstable (5) module connect with HV and DisplayPort and LV (ON). HV GND and YARR GND short -> stable 20nA@-80V | ||||||||
Changed: | ||||||||
< < | jumper connecter whom name HV and GND added which (maybe) select short with HV and sensor, HV and LV. short sensor GND - HV GND - LV GND, and short YARR - LV GND. | |||||||
> > | add jumper pin which select short with HV and bias ring. (near HV Lemo connector), and short with HV GND and bias ring. | |||||||
--> stable current !! re-setup ##run plan## (1) full depletion voltage is different with vendor and ITk. (2) tune different way: 1.target threshold:1500, include ToT tuning 2.target threshold:1500, NOT including ToT tuning for disappearing living analog core pattern. 3. target threshold:1000, ??? 11:00?? tune V6S02 : first target:2000, second target:1500, injection:10000, ToT:7, including ToT tuning 11:30 tune V6S04 : same parameters. 14:00 run control PC setup especcially editing config files. work DAQ PC from runControlPC. 14:30 first beam out 15:30 modify the stage for beam hitting sensor of RD53A as looking the monitor. 17:00 run start : DUT0:V6S02, DUT1:V6S04, both-130V, 1500e, ToT tuning ON, 10M events | ||||||||
Added: | ||||||||
> > |
27 Nov, 20199:00 stack... 10:30 tune modules with -100V, NO ToT tuning. (other parameters are same) debug 50x50 vendor6 modules, but cannot | |||||||
-- ![]() Comments |