Nov 25 ,2019

9:30 could not receive DACHS card at bld.6

Changed:
<
<
(Because My name was not in the database.)
>
>
(Because My name was not in the database.)
  10:30 registered my name in the database at bld.6 room 208

11:30 received DACHS card

13:00 safety training(listen and sign name,no test)

14:00 setup

Changed:
<
<
move last TB config file (ex.V2Sxx.json) to Sep2019_2 directory
>
>
move last TB config file (ex.V2Sxx.json) to Sep2019_2 directory
 
Changed:
<
<
make new connectivity config file:vendor6.json. and
>
>
make new connectivity config file:vendor6.json. and
 
Changed:
<
<
install V6S04/5. V6S05 is difficult to pass config. so exchange V6S05 to V6S03.
>
>
install V6S04 /5. V6S05 is difficult to pass config. so exchange V6S05 to V6S03.
  18:00 complete setup and checked digital/analog scan
Changed:
<
<
install new version YarrEudaqProducer modified for memory leak problem. change the symbolic link of YarrEudaqProducerMulti from 201907xx to 20191126
>
>
install new version YarrEudaqProducer modified for memory leak problem. change the symbolic link of YarrEudaqProducerMulti from 201907xx to 20191126
 
Changed:
<
<
apply voltage on V6S03/4, the current is so high (-50V/100uA over)
>
>
apply voltage on V6S03 /4, the current is so high (-50V/100uA over)
Added:
>
>
the cuurent droped to 0 when apply some modules of vendor2 and vendor6 with connencting to YARR. (when extract display pot cable the problem did not occur)

try to connect PC GND and LV GND, PC GND and HV GND, but the problem did not resolved.

26 Nov

9:00 maybe the promble was due to Single Chip Card?

(1) module connect with only HV -> stable, 10(?)nA@-80V

(2) module connect with HV and DiplayPort -> unstable:often drop to 0 A

(3) module connect with HV and DisplayPort and LV power supply (ON) -> unstable

(4) module connect with HV and DisplayPort and LV (ON). LV GND and YARR GND short -> unstable

(5) module connect with HV and DisplayPort and LV (ON). HV GND and YARR GND short -> stable 20nA@-80V

jumper connecter whom name HV and GND added which (maybe) select short with HV and sensor, HV and LV. short sensor GND - HV GND - LV GND, and short YARR - LV GND.

--> stable current !!

re-setup

##run plan##

(1) full depletion voltage is different with vendor and ITk.

(2) tune different way:

1.target threshold:1500, include ToT tuning

2.target threshold:1500, NOT including ToT tuning for disappearing living analog core pattern.

3. target threshold:1000, ???