MOS capacitor Measurement
MOS capacitor Measurement
First Example Measurement
ATLAS98 (現SCTのセンサー)のテストストラクチュア
First measurement results
Comments
First Example Measurement
type1 (average)
Al-SiO2-Si(0-1) : 2.6pF (50kHz~10MHz)
Al-SiO2-p+(3-4) : 130pF (1kHz~1MHz)
Al-SiN-SiO2-Si(0-2) : 55pF (5kHz~100kHz)
ATLAS98 (現SCTのセンサー)のテストストラクチュア
図面 (
ATLAS98B_HPK2225938754991217.pdf
)
--
Koji Nakamura - 2016-04-01
First measurement results
Slide from K.Sato is
here
Comments