July 22, 2019
8:00 breakfast meeting with Andre
8:40 registered DACHS card at bld. 6
9:30 received DACHS card
13:00 safety training (only listen, no test)
15:00 setup (there were many problem)
24:00 completed YARR system setup
July 23, 2019
1:00 YARR producer lauched.
1:30
RunControl PC could communicate with NI crate (telescope)
2:00 Norway 3D module did not work. it did not give signal.
3:00 revealed that
RunControl PC could not communicate with YARR producer. (YARR producer did not accept orders from RC PC.)
10:00 the above issues is resolved. we were able to go with combines telescope + FEI4 system into auto trigger run.
16:00 issues about communication with RC PC and BDAQ is resolved. But issue about Event Build happened. It was that the data from BDAQ is different with data by making from Event Build.)
17:00 confirm whether KEK53-9 by using BDAQ system work
18:00 instead of Norway 3D module, installed KEK53-13 into cooling box.
19:30 exchange YARR PC to our laptop PC because YARR PC memory is too small to work properly. copy config file from YARR PC to that one. but could not
YarrEudaqProducer files.
21:30 reload dry ice. temperature ~-1℃ -> -33℃
22:00 KEK53-13 tuning by using BDAQ. for tuning, supply KEK53-13 High Voltage=-200V.
YARR system
constraction YARR system
login user:testbeam
the YARR PC IP address -> 192.168.22.199
( BDAQ PC IP -> 192.168.22.198 )
( Run Control PC IP -> 192.168.22.1 )
( NI crate IP -> 192.168.22.2 )
install new software (
https://yarr.readthedocs.io/en/latest/install/ )
and
install new firmware (
https://yarr.web.cern.ch/yarr/firmware/ -> "2019_07_21-rd53a_ohio_3chip_1tlu-xpressk7_325.bit" )
source /opt/Xilinux/Vivado/
2016.02/settings64.sh
python flash.sh (@ ~/work/yarr_rd53a/YARR-FW(Yarr is a symbolic link with Yarr-fw_20190722)/script)
select #6 (rd53a_ohio_3chip_1tlu_xpressk7_160.bit)
if finish, reboot.
./bin/scanConsole -r configs/controller/specCfg.json -c configs/connectivity/example_rd53a_setup.json -s configs/scans/rd53a/std_digitalscan.json -p (@ ~/work/yarr_rd53a/Yarr) <- this is like rd53a_test
if some problems happened, check below things.this is when regulator mode working.
- jumper is inserted at VINA (at PWR A) and VIND (at PWR D).
- cables cnnecting with RD53A power is propely hot or GND side.
- current 480~500 mA (KEK53-9 1.85V)
- voltage drop between ~~~ and ~~~
- if it happends that voltage difference between 2 hot side pins of 4 pin, you do short by jumper inserting at JP PWR.
- GND of XpressK7 need to be GND of RD53A power
nothing problem -> tune
RD53A
this time, we used automatically tuning software by using below command.
./scripts/tune_rd53a.sh 1500 1500 10000 10 configs/controller/specCfg.json configs/connectivity/example_rd53a_setup.json
wait for 15~20min. if finish, do noise scan.
./primlist/scan53.sh noisescan KEK53-9 -m 1
./primlist/scan53.sh noisescan KEK53-9
RD53A tuning finish!!
set producer, communicate with Run Control PC
How to set YARR producer
read "README.md @~/work/yarr_rd53a/YarrEudaqProducer_20190722/
communicate with Run Control PC (The HOSTNAME variable needs to be set)
Run Control PCが命令を出すと,YARR producerがdescript? figure?を書き,memoryがoverして動作が重くなった.
->??
Can NOT communicate BDAQ producer and
RunControl PC
BDAQ tuning
How to tune
RD53A by using BDAQ system
memo
producer, communication between run control PC and BDAQ PC
cards for read out some module by creating Nakamura working test
multi module working test
--
Koji Nakamura - 2019-07-22
Comments