LogNov 25 ,20199:30 could not receive DACHS card at bld.6 (Because My name was not in the database.) 10:30 registered my name in the database at bld.6 room 208 11:30 received DACHS card 13:00 safety training(listen and sign name,no test) 14:00 setup move last TB config file (ex.V2Sxx.json) to Sep2019_2 directory make new connectivity config file:vendor6.json![]() 26 Nov, 20199:00 maybe the promble was due to Single Chip Card? (1) module connect with only HV -> stable, 10(?)nA@-80V (2) module connect with HV and DiplayPort -> unstable:often drop to 0 A (3) module connect with HV and DisplayPort and LV power supply (ON) -> unstable (4) module connect with HV and DisplayPort and LV (ON). LV GND and YARR GND short -> unstable (5) module connect with HV and DisplayPort and LV (ON). HV GND and YARR GND short -> stable 20nA@-80V add jumper pin which select short with HV and bias ring. (near HV Lemo connector), and short with HV GND and bias ring. --> stable current !! re-setup ##run plan## | ||||||||
Changed: | ||||||||
< < | (1) full depletion voltage is different with vendor and ITk. | |||||||
> > | (1) full depletion voltage is different with vendor info and ITk info. | |||||||
(2) tune different way:
1.target threshold:1500, include ToT tuning
2.target threshold:1500, NOT including ToT tuning for disappearing living analog core pattern.
3. target threshold:1000, ???
11:00?? tune V6S02 : first target:2000, second target:1500, injection:10000, ToT:7, including ToT tuning
11:30 tune V6S04 : same parameters.
14:00 run control PC setup especcially editing config files. work DAQ PC from runControlPC.
14:30 first beam out
15:30 modify the stage for beam hitting sensor of RD53A as looking the monitor.
17:00 run start : DUT0:V6S02, DUT1:V6S04, both-130V, 1500e, ToT tuning ON, 10M events
27 Nov, 20199:00 stack... 10:30 tune modules with -100V, NO ToT tuning. (other parameters are same) debug 50x50 vendor6 modules, but cannot 15:45 tune V6S02 : DiffVff =1 and V6S04 : DiffVff =1 (default Vff=50) , No ToT tuning 16:00 tune V6S02 : DiffVff =30 and V6S04 : DiffVff =30 , No ToT tuning 16:10 tune V6S02 : DiffVff =50 and V6S04 : DiffVff =50 , No ToT tuning-> default Diffvff=50 and tuned Diffvff=50 were not result 16:15 did digital scan for return default , and made new configfile->but not 1500e (in fact near 1650e) 16:30 changed DUT0 100V and DUT1=100V -> double peak... 17:00 changed DUT0 130V and DUT1=129.8V ,1000e, tune V6S02 :DiffVff=50 and V6S04 =50 , No ToT tuning28 Nov, 2019afternoon :DUT0(V6S02) tuned 1500e ToT and DUT1(V6S04) removed jumpers for grownding DUT0 changed 80V -> 100V -> 130V -> 50V -> 10V -> 30V ->130V each with 5M events DUT1 changed 130V -> 100V -> 80V -> 50V -> 30V -> 10V each with 5M events29 Nov,2019DUT0(V2S14) and DUT1(V6S05) tuned 1000e no ToT tuning ,Vff=30 DUT0 changed 75V(10M) -> 80V(5M) -> 50V(5M) ->30V(5M) DUT1 changed 130V(10M) -> 100V(5M) -> 80V(5M) -> 30V(5M) | ||||||||
Added: | ||||||||
> > |
so stable beam and DAQ systems.
each batch set is written in detail at ITk Twiki.
sometimes lost correlation.
07 Nov, 2019maybe midnight the XY stage does not work especially Y direction. in the morning, the problem had been resolved already when I knew the problem. restart data taking.08 Nov, 20199:00 clean up config and tunig file in YARR PC is copied at ~/YarrNov in Run Control PC and /eos/atlas/atlascerndisk/pixel-upgrade/itk/TestBeam/desy_2019_november/configlib24. the files do not include *.raw because of no space in Run Control PC. 2 display port - RJ45 adapter were given to Marco. Kyosuke has Linxin's one. | |||||||
-- ![]() Comments |