Article text.

-- Atlasj Silicon - 2019-12-27

prepare and update

rasbpi temperature reading system

CYRICにて,温度読み出しで,パネル越しだととてもNoisyで測定される温度が不安定な問題.

  • (正確には,パネル越しでなく,7m長のcableで行ってもnoisyだった.)
  • analog signalのcable長によるnoise変化
  • →KEKにてNTC-raspi adapter board (ADC搭載) 間のcableを約30mに変更
  • →変化なし(±4℃くらいのずれで,安定)
  • noiseを減らすためにadapter board改良
  • = U_NTC1-2のLow側とGNDの間にcapacitor (100nF)を繋げる.
  • ~ R4とR8それぞれにcapacitorをpararellに接続(R4とR8はAC的にGND@VREFF)
  • →parelell接続
  • →KEKでのテストではほとんど変化なし(同じく安定).CYRICで安定化すればいい...

Comments